Machine technical sheet


Immagine rappresentane il macchinario
Brand: Biotronic Advance Develops (Spagna)
Model: DTI System Solution
Type: Beauty treatments - apparatus for the partial treatment of heat through radiofrequency
Power: 0.17 kW
Power supply: Electrical (220V-380V)
Reference standard: CEI 62-39 - abrogata dal 2016
Frequency of work: 1 - 65000 kHz
Type of emission: Continua
Type of radiant element: Capacitivo
Category according to 12198-1-12009 Standard: Non disponibile
Required protection measures:
  1. Delimit Zone 1: Exposure values above the reference levels for general public
  2. Delimit Zone 2: Exposure values above the action levels for workers
  3. The access to the Restricted areas shall be permitted only to those individuals with proven absence of contraindications to EMF exposure

Measurements in the field (Click to view the measurements in the field)

Reference person:

AUSL 7 Siena - Laboratorio Agenti Fisici Nicola Stacchini ([email protected])
SIZE AND SHAPE OF THE APPLICATOR [m]
X 0.05 SHAPE

Cylindrical
Y 0.04
Z -
Measuring point Reference Distance Perpendicular [cm] Distance Parallel [cm] Height from ground [cm] Frequency dominant [Hz] FIGURE MEASURED ENTITY MEASURED VALUE NOTES
P2
applicatore
10 - - 900000 % reference level General Public council recommendation 1999/519/CE Electrical Stimulation [Electric Field] 115 % Manipolo piccolo potenza 50%
P2
applicatore
10 - - 900000 Percentage reference level General Public council recommendation 1999/519/CE Thermal Effect [Electric Field] 105 % sul valore massimo Manipolo piccolo potenza 50%
P3
applicatore
10 - - 900000 % reference level General Public council recommendation 1999/519/CE Electrical Stimulation [Magnetic Field] 1 % Manipolo piccolo potenza 50%
P4
Testa Operatore
10 - - 900000 % reference level General Public council recommendation 1999/519/CE Electrical Stimulation [Electric Field] 55 % Manipolo piccolo Riferimento: testa potenza 50%
P5
cavo connessione
20 - - 900000 % reference level General Public council recommendation 1999/519/CE Electrical Stimulation [Electric Field] 480 % Manipolo piccolo potenza 50%
P5
cavo connessione
20 - - 900000 Percentage reference level General Public council recommendation 1999/519/CE Thermal Effect [Electric Field] 1850 % sul valore massimo Manipolo piccolo potenza 50%
P6
parete laterale
10 - - 900000 % reference level General Public council recommendation 1999/519/CE Electrical Stimulation [Electric Field] 50 % Manipolo piccolo potenza 50%
P7
applicatore
10 - - 900000 % reference level General Public council recommendation 1999/519/CE Electrical Stimulation [Electric Field] 235 % Manipolo grande potenza 80%
P8
applicatore
10 - - 900000 % reference level General Public council recommendation 1999/519/CE Electrical Stimulation [Magnetic Field] 1 % Manipolo grande potenza 80%
Zona 0 è la zona all’interno della quale i livelli di esposizione sono sicuramente inferiori o uguali ai livelli di riferimento della popolazione (conformità alla raccomandazione 1999/519/CE) Distanze maggiori di 1.5 m
Zona 1 è la zona all’interno della quale i livelli di esposizione superano i livelli di riferimento della popolazione ma sono inferiori o uguali ai valori di AZIONE INFERIORI per i lavoratori stabiliti dal Decreto Legislativo n. 81/2008 Distanze inferiori a 1.5 m
Zona 2 è la zona nella quale i livelli di esposizione superano i livelli di AZIONE INFERIORI per i lavoratori stabiliti dal Decreto Legislativo n. 81/2008 assente