Machine technical sheet


Immagine rappresentane il macchinario
Brand: Cesare Quaranta S.r.l.
Model: Q-Frequency Light
Type: Beauty treatments - apparatus for the partial treatment of heat through radiofrequency
Power: 0.25 kW
Power supply: Electrical (220V-380V)
Reference standard: CEI 62-39 - abrogata dal 2016
Frequency of work: 1 - 65000 kHz
Type of emission: Continua
Type of radiant element: Capacitivo
Category according to 12198-1-12009 Standard: Non disponibile
Required protection measures:
  1. Delimit Zone 1: Exposure values above the reference levels for general public
  2. Delimit Zone 2: Exposure values above the action levels for workers
  3. The access to the Restricted areas shall be permitted only to those individuals with proven absence of contraindications to EMF exposure
  4. The worker is exposed to levels of electromagnetic fields exceeding the action levels for WORKERS.

Measurements in the field (Click to view the measurements in the field)

Reference person:

AUSL 7 Siena - Laboratorio Agenti Fisici Nicola Stacchini ([email protected])
SIZE AND SHAPE OF THE APPLICATOR [m]
X 0.03 SHAPE

Cylindrical
Y 0.003
Z -
Measuring point Reference Distance Perpendicular [cm] Distance Parallel [cm] Height from ground [cm] Frequency dominant [Hz] FIGURE MEASURED ENTITY MEASURED VALUE NOTES
P1
applicatore
10 - - 500000 Percentage reference level General Public council recommendation 1999/519/CE Thermal Effect [Electric Field] 990 % sul valore massimo Manipolo grande potenza 45%
P1
applicatore
10 - - 500000 % reference level General Public council recommendation 1999/519/CE Electrical Stimulation [Magnetic Field] 5 % Manipolo grande potenza 45%
P2
applicatore
10 - - 500000 % reference level General Public council recommendation 1999/519/CE Electrical Stimulation [Electric Field] 580 % Manipolo medio potenza 45%
P2
applicatore
10 - - 500000 Percentage reference level General Public council recommendation 1999/519/CE Thermal Effect [Electric Field] 1250 % sul valore massimo Manipolo medio potenza 45%
P3
applicatore
10 - - 500000 % reference level General Public council recommendation 1999/519/CE Electrical Stimulation [Electric Field] 700 % Manipolo piccolo potenza 60%
P3
applicatore
10 - - 500000 Percentage reference level General Public council recommendation 1999/519/CE Thermal Effect [Electric Field] 1850 % sul valore massimo Manipolo piccolo potenza 60%
P3
applicatore
10 - - 500000 % reference level General Public council recommendation 1999/519/CE Electrical Stimulation [Magnetic Field] 2 % Manipolo piccolo potenza 60%
P4
Testa Operatore
10 - - 500000 Percentage reference level General Public council recommendation 1999/519/CE Thermal Effect [Electric Field] 790 % sul valore massimo Manipolo piccolo potenza 60%
P5
applicatore
200 - - 500000 % reference level General Public council recommendation 1999/519/CE Electrical Stimulation [Electric Field] 30 % Manipolo piccolo potenza 60%
Zona 0 è la zona all’interno della quale i livelli di esposizione sono sicuramente inferiori o uguali ai livelli di riferimento della popolazione (conformità alla raccomandazione 1999/519/CE) Distanze maggiori di 2 m
Zona 1 è la zona all’interno della quale i livelli di esposizione superano i livelli di riferimento della popolazione ma sono inferiori o uguali ai valori di azione per i lavoratori stabiliti dalla Direttiva 2004/40/CE Distanze comprese tra 1 m e 2 m
Zona 2 è la zona nella quale i livelli di esposizione superano i livelli di azione stabiliti dalla Direttiva 2004/40/CE Distanze inferiori a 1 m

Note
logo regione toscana
Regione Toscana
Diritti Valori Innovazione Sostenibilità
collegamento sito usl 7 siena Servizio Sanitario
della
Toscana