Machine technical sheet


Immagine rappresentane il macchinario
Brand: DÜRKOPP ADLER AG Germany
Model: 467 AE 73
Type: Sewing machine
Power supply: Electrical (220V-380V)
Reference standard: CEI EN 62233
Frequency of work: Non disponibile
Type of emission: Non disponibile
Type of radiant element: Non disponibile
Category according to 12198-1-12009 Standard: Non disponibile
Required protection measures:

Measurements in the field (Click to view the measurements in the field)

Reference person:

AUSL 7 Siena - Laboratorio Agenti Fisici Andrea Bogi ([email protected])
SIZE AND SHAPE OF THE APPLICATOR [m]
X - SHAPE
Non Disponibile
Y -
Z -
Measuring point Reference Distance Perpendicular [cm] Distance Parallel [cm] Height from ground [cm] Frequency dominant [Hz] FIGURE MEASURED ENTITY MEASURED VALUE NOTES
P1
direzione sottostante apparato
10 0 70 50 Reference level General Public council racommendation 1999/519/EC [Magnetic Field] 37 %
P1
direzione sottostante apparato
10 0 70 50 Als Workers UE Directive 2004/40/EC [Magnetic Field] 7 %
P1
direzione sottostante apparato
10 0 70 50 Magnetic Field 52 microT
Zona 0 è la zona all’interno della quale i livelli di esposizione sono sicuramente inferiori o uguali ai livelli di riferimento della popolazione (conformità alla raccomandazione 1999/519/CE) a qualsiasi distanza
Zona 1 è la zona all’interno della quale i livelli di esposizione superano i livelli di riferimento della popolazione ma sono inferiori o uguali ai valori di azione per i lavoratori stabiliti dalla Direttiva 2004/40/CE assente
Zona 2 è la zona nella quale i livelli di esposizione superano i livelli di azione stabiliti dalla Direttiva 2004/40/CE assente

Note
Valori massimi ottenuti in corrispondenza ginocchia operatrice. Sono riportati i valori massimi.
logo regione toscana
Regione Toscana
Diritti Valori Innovazione Sostenibilità
collegamento sito usl 7 siena Servizio Sanitario
della
Toscana