Machine technical sheet


Immagine rappresentane il macchinario
Brand: 3 M
Model: 3802
Type: Electronic article surveillance (EAS) systems, magnetic gates and similar ones
Built in 1995
Weight: 106 kg
Power supply: Electrical (220V-380V)
Reference standard: CEI EN 50357
Frequency of work: 0 - 1000 Hz
Type of emission: Continua
Type of radiant element: Induttivo
Category according to 12198-1-12009 Standard: Non disponibile
Required protection measures:

Measurements in the field (Click to view the measurements in the field)

Reference person:

AUSL 7 Siena - Laboratorio Agenti Fisici Andrea Bogi ([email protected])
SIZE AND SHAPE OF THE APPLICATOR [m]
X 1.13 SHAPE

Parallelepipedal
Y 1.78
Z 0.6
Measuring point Reference Distance Perpendicular [cm] Distance Parallel [cm] Height from ground [cm] Frequency dominant [Hz] FIGURE MEASURED ENTITY MEASURED VALUE NOTES
P1
applicatore
0 0 130 200 Reference level General Public council racommendation 1999/519/EC [Magnetic Field] 1000 %
P2
lato destro apparato
0 0 130 200 Reference level General Public council racommendation 1999/519/EC [Magnetic Field] 1300 %
P3
applicatore destro
0 100 130 200 Reference level General Public council racommendation 1999/519/EC [Magnetic Field] 30 %
Zona 0 è la zona all’interno della quale i livelli di esposizione sono sicuramente inferiori o uguali ai livelli di riferimento della popolazione (conformità alla raccomandazione 1999/519/CE) Distanze maggiori di 1 m
Zona 1 è la zona all’interno della quale i livelli di esposizione superano i livelli di riferimento della popolazione ma sono inferiori o uguali ai valori di azione per i lavoratori stabiliti dalla Direttiva 2004/40/CE Distanze minore di 1 m
Zona 2 è la zona nella quale i livelli di esposizione superano i livelli di azione stabiliti dalla Direttiva 2004/40/CE assente

Note