Machine technical sheet


Immagine rappresentane il macchinario
Brand: DeltaFlux Impianti s.r.l.
Model: DF G 60 MC AC/DC
Type: Magnetic particle inspection machine
Built in 2015
Power: 40 kW
Power supply: Electrical (220V-380V)
Reference standard: Non Identificata
Frequency of work: 0 - 1000 Hz
Type of emission: Pulsata
Type of radiant element: Induttivo
Category according to 12198-1-12009 Standard: Non disponibile
Required protection measures:
  1. Delimit Zone 1: Exposure values above the reference levels for general public

Measurements in the field (Click to view the measurements in the field)

Reference person:

Dip. Energia Politecnico di Torino Luca, Giaccone ([email protected])
SIZE AND SHAPE OF THE APPLICATOR [m]
X 0.2 SHAPE

Cylindrical
Y 0.2
Z 3
Measuring point Reference Distance Perpendicular [cm] Distance Parallel [cm] Height from ground [cm] Frequency dominant [Hz] FIGURE MEASURED ENTITY MEASURED VALUE NOTES
P3
Non disponibile
80 150 100 50 Magnetic Field 673 microT
P3
Non disponibile
80 150 100 50 Reference level General Public council racommendation 1999/519/EC [Magnetic Field] 1119.6 %
P3
Non disponibile
80 150 100 50 Low Als Workers UE Directive 2013/35/EC [Magnetic Field] 55.98 %
P8
Non disponibile
150 150 100 50 Magnetic Field 280 microT
P8
Non disponibile
150 150 100 50 Reference level General Public council racommendation 1999/519/EC [Magnetic Field] 514.6 %
P8
Non disponibile
150 150 100 50 Low Als Workers UE Directive 2013/35/EC [Magnetic Field] 25.73 %
P13
Non disponibile
250 150 100 50 Magnetic Field 66.6 microT
P13
Non disponibile
250 150 100 50 Reference level General Public council racommendation 1999/519/EC [Magnetic Field] 161.8 %
P13
Non disponibile
250 150 100 50 Low Als Workers UE Directive 2013/35/EC [Magnetic Field] 8.09 %
Zona 0 è la zona all’interno della quale i livelli di esposizione sono sicuramente inferiori o uguali ai livelli di riferimento della popolazione (conformità alla raccomandazione 1999/519/CE) Distanze maggiori di 2.8 m
Zona 1 è la zona all’interno della quale i livelli di esposizione superano i livelli di riferimento della popolazione ma sono inferiori o uguali ai valori di azione per i lavoratori stabiliti dalla Direttiva 2004/40/CE Distanze comprese tra 0 m e 2.8 m
Zona 2 è la zona nella quale i livelli di esposizione superano i livelli di azione stabiliti dalla Direttiva 2004/40/CE Distanze inferiori a 0 m

Note
configurazione magnetoscopio con funzionamento mediante contatto diretto
A report is available for this measure

Reference person:

Dip. Energia Politecnico di Torino Luca, Giaccone ([email protected])
SIZE AND SHAPE OF THE APPLICATOR [m]
X 0.4 SHAPE

Cylindrical
Y 0.1
Z 0.4
Measuring point Reference Distance Perpendicular [cm] Distance Parallel [cm] Height from ground [cm] Frequency dominant [Hz] FIGURE MEASURED ENTITY MEASURED VALUE NOTES
P1
Non disponibile
80 0 100 50 Magnetic Field 340 microT
P1
Non disponibile
80 0 100 50 Reference level General Public council racommendation 1999/519/EC [Magnetic Field] 640.2 %
P1
Non disponibile
80 0 100 50 Low Als Workers UE Directive 2013/35/EC [Magnetic Field] 32.01 %
P2
Non disponibile
150 0 100 50 Magnetic Field 94 microT
P2
Non disponibile
150 0 100 50 Reference level General Public council racommendation 1999/519/EC [Magnetic Field] 210.4 %
P2
Non disponibile
150 0 100 50 Low Als Workers UE Directive 2013/35/EC [Magnetic Field] 10.52 %
P3
Non disponibile
250 0 100 50 Magnetic Field 12 microT
P3
Non disponibile
250 0 100 50 Reference level General Public council racommendation 1999/519/EC [Magnetic Field] 85.6 %
P3
Non disponibile
250 0 100 50 Low Als Workers UE Directive 2013/35/EC [Magnetic Field] 4.28 %
Zona 0 è la zona all’interno della quale i livelli di esposizione sono sicuramente inferiori o uguali ai livelli di riferimento della popolazione (conformità alla raccomandazione 1999/519/CE) Distanze maggiori di 2.3 m
Zona 1 è la zona all’interno della quale i livelli di esposizione superano i livelli di riferimento della popolazione ma sono inferiori o uguali ai valori di azione per i lavoratori stabiliti dalla Direttiva 2004/40/CE Distanze comprese tra 0 m e 2.3 m
Zona 2 è la zona nella quale i livelli di esposizione superano i livelli di azione stabiliti dalla Direttiva 2004/40/CE Distanze inferiori a 0 m

Note
configurazione magnetoscopio con funzionamento mediante bobina
A report is available for this measure