Machine technical sheet


Immagine rappresentane il macchinario
Brand: We, The Pully Beauty Limited - China
Model: IB-RF02 Radio Frequency Beauty
Type: Beauty treatments - apparatus for the partial treatment of heat through radiofrequency
Power: 0.1 kW
Power supply: Electrical (220V-380V)
Reference standard: CEI 62-39 - abrogata dal 2016
Frequency of work: 1 - 65000 kHz
Type of emission: Continua
Type of radiant element: Capacitivo
Category according to 12198-1-12009 Standard: Non disponibile
Required protection measures:
  1. Delimit Zone 1: Exposure values above the reference levels for general public
  2. Delimit Zone 2: Exposure values above the action levels for workers
  3. The access to the Restricted areas shall be permitted only to those individuals with proven absence of contraindications to EMF exposure

Measurements in the field (Click to view the measurements in the field)

Reference person:

AUSL 7 Siena - Laboratorio Agenti Fisici Nicola Stacchini ([email protected])
SIZE AND SHAPE OF THE APPLICATOR [m]
X 0.045 SHAPE

Cylindrical
Y -
Z -
Measuring point Reference Distance Perpendicular [cm] Distance Parallel [cm] Height from ground [cm] Frequency dominant [Hz] FIGURE MEASURED ENTITY MEASURED VALUE NOTES
P1
applicatore
20 - 100 250000 % reference level General Public council recommendation 1999/519/CE Electrical Stimulation [Electric Field] 1200 % Manipolo medio
P1
applicatore
20 - 100 250000 Percentage reference level General Public council recommendation 1999/519/CE Thermal Effect [Electric Field] 2300 % sul valore massimo Manipolo medio
P1
applicatore
20 - 100 250000 Als Workers UE Directive 2004/40/EC [Electric Field] 780 % Manipolo medio
P2
Testa Operatore
10 - 100 250000 % reference level General Public council recommendation 1999/519/CE Electrical Stimulation [Electric Field] 800 % Manipolo medio
P2
Testa Operatore
10 - 100 250000 Percentage reference level General Public council recommendation 1999/519/CE Thermal Effect [Electric Field] 1000 % sul valore massimo Manipolo medio
P3
applicatore
30 - 100 250000 % reference level General Public council recommendation 1999/519/CE Electrical Stimulation [Electric Field] 1700 % Manipolo medio
P3
applicatore
30 - 100 250000 Percentage reference level General Public council recommendation 1999/519/CE Thermal Effect [Electric Field] 5500 % sul valore massimo Manipolo medio
P4
applicatore
80 - 100 250000 % reference level General Public council recommendation 1999/519/CE Electrical Stimulation [Electric Field] 450 % Manipolo medio
P4
applicatore
80 - 100 250000 Percentage reference level General Public council recommendation 1999/519/CE Thermal Effect [Electric Field] 320 % sul valore massimo Manipolo medio
Zona 0 è la zona all’interno della quale i livelli di esposizione sono sicuramente inferiori o uguali ai livelli di riferimento della popolazione (conformità alla raccomandazione 1999/519/CE) Distanze maggiori di 3 m
Zona 1 è la zona all’interno della quale i livelli di esposizione superano i livelli di riferimento della popolazione ma sono inferiori o uguali ai valori di AZIONE INFERIORI per i lavoratori stabiliti dal Decreto Legislativo n. 81/2008 Distanze comprese tra 2 m e 3 m
Zona 2 è la zona nella quale i livelli di esposizione superano i livelli di AZIONE INFERIORI per i lavoratori stabiliti dal Decreto Legislativo n. 81/2008 Distanze inferiori a 2 m

Note
logo regione toscana
Regione Toscana
Diritti Valori Innovazione Sostenibilità
collegamento sito usl 7 siena Servizio Sanitario
della