Machine technical sheet


Immagine rappresentane il macchinario
Brand: Tractel Solutions
Model: Mag For II 500
Type: Magnetic Lifts with manual control
Weight: 18 kg
Power supply: Manual
Reference standard: Non Identificata
NOTE: The limit value for exposure of DMIA wearers to the static magnetic field of 0.5 mT is reached at a distance of about 30 cm from the device. Avoid that such subjects standing with their torso at a shorter distance.

Frequency of work: 0 - 1000 Hz
Type of emission: Continua
Type of radiant element: Induttivo
Category according to 12198-1-12009 Standard: Non disponibile
Required protection measures:
  1. AIMD wearers are advised to keep the device at a distance greater than the magnetic field value compliance distance of 0.5mT

Measurements in the field (Click to view the measurements in the field)

Reference person:

Viviana Propato Viviana Propato ()
SIZE AND SHAPE OF THE APPLICATOR [m]
X - SHAPE

Cubical
Y -
Z -
Measuring point Reference Distance Perpendicular [cm] Distance Parallel [cm] Height from ground [cm] Frequency dominant [Hz] FIGURE MEASURED ENTITY MEASURED VALUE NOTES
P1
fronte apparato
100 - - - Magnetic Field 175 microT campo magnetico statico
P2
fronte apparato
30 - - - Magnetic Field 500 microT campo magnetico statico
Zona 0 è la zona all’interno della quale i livelli di esposizione sono sicuramente inferiori o uguali ai livelli di riferimento della popolazione (conformità alla raccomandazione 1999/519/CE) a qualsiasi distanza
Zona 1 è la zona all’interno della quale i livelli di esposizione superano i livelli di riferimento della popolazione ma sono inferiori o uguali ai valori di azione per i lavoratori stabiliti dalla Direttiva 2004/40/CE assente
Zona 2 è la zona nella quale i livelli di esposizione superano i livelli di azione stabiliti dalla Direttiva 2004/40/CE assente