Machine technical sheet


Brand: HILTI
Model: TE 104
Type: Rock drills and rotary hammers
Built in: n.d.
Weight: 3.5 kg
Power: 0.55 kW
Power supply: Electrical (220V-380V)
Anti-vibration devices: Absent
Source of the data: Acquisito sul campo da misuratore

Immagine rappresentante la tipologia
Declared values as set forth in the standard EN 50144-2-6
( x 2,0 Hammer drilling, Chiseling, Drilling without impact - x 1,5 Breaking concrete/masonry )
CONDITIONS MATERIAL ACCESSORY VALUE K(1) Note
NOT ASSESSEDNOT ASSESSEDNOT ASSESSED9 m/s2
(1) Expanded uncertainty

Measurements in the field (Click to view the measurements in the field)

Reference person: CPT Perugia ([email protected])
Location: TODI (PG) on 05/04/2007
Features of the accessory: Pick, moil point
domDebug Array ( [id] => 350 [data] => 2007-04-05 [referente] => 12 [dichiarazione_di_pubblicabilita] => [luogo] => TODI (PG) [comparto] => Costruzioni edili [numero_di_serie] => [accessorio_usato] => 1057 [t_lavoro_effettuato] => 6 [materiale_lavorato] => 203 [leq] => 0 [note] => [foto1] => [foto2] => [foto3] => [pressione] => [frequenza] => [isValid] => Yes [referente2] => 12 [caratteristicheAccessorio] => PUNTA [durata] => [en_luogo] => [importato] => Yes [caratteristicheLavoroEffettuato] => DEMOLIZIONE [caratteristicheMateriale] => PIETRA [en_note] => [id_anagrafica_generale] => 151 [owner_user] => 0 [stato] => [id_modello_strumento_di_misura] => 0 [id_sensore_strumento_di_misura] => 0 [id_adattatore_del_sensore] => 0 [accessorio] => Punta piramidale, punta conica [en_accessorio] => Pick, moil point [materiale] => Pietra [en_materiale] => Stone [denominazione] => CPT Perugia [nome_cognome] => [tel] => 0755059411 [email] => [email protected] [username] => cptperugia [categoria] => 2 [lavoro] => Demolizione [en_lavoro] => Demolition [en_comparto] => Building constructions )

Values related to the vibration worst case handle ​ ( Right )
A hx (Mean)
6.5 m/s2
A hy (Mean)
6 m/s2
A hz (Mean)
2 m/s2
A hv sum
9 m/s2
Standard deviation
0.6 m/s2
Standard deviation
0.65 m/s2
Standard deviation
0.06 m/s2
Standard deviation x 1,645:
0.99 m/s2
Mean
+ Standard deviation:
7.1 m/s2
Mean
+ Standard deviation:
6.7 m/s2
Mean
+ Standard deviation:
2.1 m/s2
A hv sum
+ (Dev. std. x 1,645):
10 m/s2
Reference person: CPT Torino ([email protected])
Location: VISCHE (CN) on 15/02/2007
Features of the accessory: Pick, moil point
domDebug Array ( [id] => 591 [data] => 2007-02-15 [referente] => 14 [dichiarazione_di_pubblicabilita] => [luogo] => VISCHE (CN) [comparto] => Costruzioni edili [numero_di_serie] => [accessorio_usato] => 1057 [t_lavoro_effettuato] => 6 [materiale_lavorato] => 203 [leq] => 0 [note] => scheda 281 [foto1] => [foto2] => [foto3] => [pressione] => [frequenza] => [isValid] => Yes [referente2] => 14 [caratteristicheAccessorio] => punta da 10 [durata] => [en_luogo] => [importato] => Yes [caratteristicheLavoroEffettuato] => demolizione [caratteristicheMateriale] => pietra [en_note] => [id_anagrafica_generale] => 151 [owner_user] => 0 [stato] => [id_modello_strumento_di_misura] => 0 [id_sensore_strumento_di_misura] => 0 [id_adattatore_del_sensore] => 0 [accessorio] => Punta piramidale, punta conica [en_accessorio] => Pick, moil point [materiale] => Pietra [en_materiale] => Stone [denominazione] => CPT Torino [nome_cognome] => [tel] => 0113400311 [email] => [email protected] [username] => cpttorino [categoria] => 2 [lavoro] => Demolizione [en_lavoro] => Demolition [en_comparto] => Building constructions )

Values related to the vibration worst case handle ​ ( Right )
A hx (Mean)
2.8 m/s2
A hy (Mean)
3.7 m/s2
A hz (Mean)
4.4 m/s2
A hv sum
6.4 m/s2
Standard deviation
0.12 m/s2
Standard deviation
0.08 m/s2
Standard deviation
0.32 m/s2
Standard deviation x 1,645:
0.37 m/s2
Mean
+ Standard deviation:
2.9 m/s2
Mean
+ Standard deviation:
3.8 m/s2
Mean
+ Standard deviation:
4.7 m/s2
A hv sum
+ (Dev. std. x 1,645):
6.8 m/s2
Reference person: CPT Cagliari ([email protected])
Location: Cagliari - Via Barone Rossi on 19/09/2006
Features of the accessory: Chisel
domDebug Array ( [id] => 95 [data] => 2006-09-19 [referente] => 11 [dichiarazione_di_pubblicabilita] => [luogo] => Cagliari - Via Barone Rossi [comparto] => Costruzioni edili [numero_di_serie] => [accessorio_usato] => 1058 [t_lavoro_effettuato] => 6 [materiale_lavorato] => 197 [leq] => [note] => [foto1] => [foto2] => [foto3] => [pressione] => [frequenza] => [isValid] => Yes [referente2] => 11 [caratteristicheAccessorio] => Scalpello [durata] => [en_luogo] => [importato] => Yes [caratteristicheLavoroEffettuato] => Demolizione [caratteristicheMateriale] => Intonaco [en_note] => [id_anagrafica_generale] => 151 [owner_user] => 0 [stato] => [id_modello_strumento_di_misura] => 0 [id_sensore_strumento_di_misura] => 0 [id_adattatore_del_sensore] => 0 [accessorio] => Scalpello [en_accessorio] => Chisel [materiale] => Malta edile essiccata [en_materiale] => Mortar [denominazione] => CPT Cagliari [nome_cognome] => [tel] => 0702084120 [email] => [email protected] [username] => cptcagliari [categoria] => 2 [lavoro] => Demolizione [en_lavoro] => Demolition [en_comparto] => Building constructions )

Values related to the vibration worst case handle ​ ( Posterior )
A hx (Mean)
6.9 m/s2
A hy (Mean)
4.2 m/s2
A hz (Mean)
2.8 m/s2
A hv sum
8.5 m/s2
Standard deviation
0.35 m/s2
Standard deviation
0.15 m/s2
Standard deviation
0.16 m/s2
Standard deviation x 1,645:
0.41 m/s2
Mean
+ Standard deviation:
7.3 m/s2
Mean
+ Standard deviation:
4.4 m/s2
Mean
+ Standard deviation:
3 m/s2
A hv sum
+ (Dev. std. x 1,645):
8.9 m/s2
Reference person: CPT Cagliari ([email protected])
Location: Selargius (CA) on 30/11/2006
Features of the accessory: Chisel
domDebug Array ( [id] => 128 [data] => 2006-11-30 [referente] => 11 [dichiarazione_di_pubblicabilita] => [luogo] => Selargius (CA) [comparto] => Costruzioni edili [numero_di_serie] => [accessorio_usato] => 1058 [t_lavoro_effettuato] => 6 [materiale_lavorato] => 191 [leq] => 0 [note] => [foto1] => [foto2] => [foto3] => [pressione] => [frequenza] => [isValid] => Yes [referente2] => 11 [caratteristicheAccessorio] => Scalpello [durata] => [en_luogo] => [importato] => Yes [caratteristicheLavoroEffettuato] => Demolizione [caratteristicheMateriale] => Calcestruzzo [en_note] => [id_anagrafica_generale] => 151 [owner_user] => 0 [stato] => [id_modello_strumento_di_misura] => 0 [id_sensore_strumento_di_misura] => 0 [id_adattatore_del_sensore] => 0 [accessorio] => Scalpello [en_accessorio] => Chisel [materiale] => Calcestruzzo [en_materiale] => Concrete [denominazione] => CPT Cagliari [nome_cognome] => [tel] => 0702084120 [email] => [email protected] [username] => cptcagliari [categoria] => 2 [lavoro] => Demolizione [en_lavoro] => Demolition [en_comparto] => Building constructions )

Values related to the vibration worst case handle ​ ( Posterior )
A hx (Mean)
7 m/s2
A hy (Mean)
3.5 m/s2
A hz (Mean)
4.4 m/s2
A hv sum
9 m/s2
Standard deviation
0.11 m/s2
Standard deviation
0.1 m/s2
Standard deviation
0.11 m/s2
Standard deviation x 1,645:
0.26 m/s2
Mean
+ Standard deviation:
7.1 m/s2
Mean
+ Standard deviation:
3.6 m/s2
Mean
+ Standard deviation:
4.5 m/s2
A hv sum
+ (Dev. std. x 1,645):
9.3 m/s2
logo regione toscana
Regione Toscana
Diritti Valori Innovazione Sostenibilità
collegamento sito usl 7 siena Servizio Sanitario
della
Toscana
eventi
CORSO FAD SINCRONA
Esposizione occupazionale ai campi
elettromagnetici
06-07 maggio
Corso online
~
CORSO AIDII TER
II EDIZIONE
19-22-27 maggio
e 3 giugno 2025
Corso online
~
Corso di formazione
Rischio VIBRAZIONI
03 giugno 2025
Corso online
~
Corso di formazione
Rischio RUMORE
06 giugno 2025
Corso online
~
Corso di formazione
Rischio MICROCLIMA
7 luglio 2025
Corso online
~
Corso di aggiornamento
Rischio MICROCLIMA
2 Aprile 2025
Corso online
~
Rischio ULTRASUONI
Aggiornamenti e strumenti operativi
2 Aprile 2025
Corso online
~
Corso AIDII TER
Valutatore di radiazioni ottiche
1-3-8-10 Aprile 2025
Corso online
~
Corso di formazione
Il rischio da agenti fisici:
Fondamenti
30 e 31 Gennaio 2025
CNR Area Territoriale di Ricerca di Firenze
~
Corso di alta formazione
Gestione integrata del rischio da agenti fisici
Scadenza presentazione
23 gennaio 2025
Sapienza- Università di Roma
~
Rischio da esposizione a vibrazione:
valutazione e controllo
in differenti condizioni espositive
10 Dicembre 2024
Corso online
~
Rischio rumore:
valutazione e controllo
in differenti condizioni espositive
28 Novembre 2024
Corso online
~
Corso di formazione:
Microclima
Rischio alla luce
dei cambiamenti climatici
7 Novembre 2024
Corso online
~
Corso di formazione:
Rischio da esposizione a rumore
14 Ottebre
Corso online
~
Convegno Nazionale
OspedaleSicuro Duemila24
3 e 4 Ottobre 2024
Università degli studi di Napoli "Federico II"
~
Corso di formazione:
Rischio da esposizione a rumore
7 Maggio 2024
Corso online
~
Corso di formazione:
Microclima
per Associazione
Ambientale Lavoro
27 Febbraio 2024
Corso online
~
Giornata Studio:
Valutazione e gestione
del rischio da esposizione
31 Ottobre 2023
Politecnico di Torino
~
Corso di formazione:
Ultrasuoni - Microclima
Vibrazioni
30 Novembre - 1° Dicembre 2023
~