Machine technical sheet


Brand: HILTI
Model: TE 6C
Type: Rock drills and rotary hammers
Built in: n.d.
Weight: 0.9 kg
Power: 0.6 kW
Power supply: Electrical (220V-380V)
Anti-vibration devices: Absent
Source of the data: Acquisito sul campo da misuratore

Immagine rappresentante la tipologia
Declared values as set forth in the standard EN 50144-2-6
( x 2,0 Hammer drilling, Chiseling, Drilling without impact - x 1,5 Breaking concrete/masonry )
CONDITIONS MATERIAL ACCESSORY VALUE K(1) Note
NOT ASSESSEDNOT ASSESSEDNOT ASSESSED8 m/s2
(1) Expanded uncertainty

Measurements in the field (Click to view the measurements in the field)

Reference person: CPT Perugia ([email protected])
Location: PERUGIA (PG) on 21/03/2007
Features of the accessory: NOT ASSESSED

Values related to the vibration worst case handle ​ ( Left )
A hx (Mean)
7.6 m/s2
A hy (Mean)
9.2 m/s2
A hz (Mean)
6.3 m/s2
A hv sum
13.5 m/s2
Standard deviation
0.44 m/s2
Standard deviation
0.45 m/s2
Standard deviation
0.11 m/s2
Standard deviation x 1,645:
0.86 m/s2
Mean
+ Standard deviation:
8 m/s2
Mean
+ Standard deviation:
9.7 m/s2
Mean
+ Standard deviation:
6.4 m/s2
A hv sum
+ (Dev. std. x 1,645):
14.4 m/s2
Reference person: CPT Torino ([email protected])
Location: GRUGLIASCO (TO) on 05/02/2007
Features of the accessory: NOT ASSESSED

Values related to the vibration worst case handle ​ ( Posterior )
A hx (Mean)
5 m/s2
A hy (Mean)
5.6 m/s2
A hz (Mean)
3.6 m/s2
A hv sum
8.4 m/s2
Standard deviation
0.42 m/s2
Standard deviation
0.71 m/s2
Standard deviation
0.29 m/s2
Standard deviation x 1,645:
1.4 m/s2
Mean
+ Standard deviation:
5.4 m/s2
Mean
+ Standard deviation:
6.3 m/s2
Mean
+ Standard deviation:
3.9 m/s2
A hv sum
+ (Dev. std. x 1,645):
9.8 m/s2
Reference person: CPT Perugia ([email protected])
Location: PERUGIA (PG) on 23/05/2007
Features of the accessory: NOT ASSESSED

Values related to the vibration worst case handle ​ ( Left )
A hx (Mean)
6.3 m/s2
A hy (Mean)
5.8 m/s2
A hz (Mean)
5.4 m/s2
A hv sum
10.1 m/s2
Standard deviation
0.18 m/s2
Standard deviation
0.67 m/s2
Standard deviation
0.28 m/s2
Standard deviation x 1,645:
0.36 m/s2
Mean
+ Standard deviation:
6.5 m/s2
Mean
+ Standard deviation:
6.5 m/s2
Mean
+ Standard deviation:
5.7 m/s2
A hv sum
+ (Dev. std. x 1,645):
10.5 m/s2
Reference person: CPT Cagliari ([email protected])
Location: Selargius (CA) on 05/04/2007
Features of the accessory: Pick, moil point

Values related to the vibration worst case handle ​ ( Posterior )
A hx (Mean)
9.3 m/s2
A hy (Mean)
10.1 m/s2
A hz (Mean)
6.4 m/s2
A hv sum
15.2 m/s2
Standard deviation
0.08 m/s2
Standard deviation
0.12 m/s2
Standard deviation
0.11 m/s2
Standard deviation x 1,645:
0.28 m/s2
Mean
+ Standard deviation:
9.4 m/s2
Mean
+ Standard deviation:
10.2 m/s2
Mean
+ Standard deviation:
6.5 m/s2
A hv sum
+ (Dev. std. x 1,645):
15.5 m/s2
Reference person: CPT Torino ([email protected])
Location: VINOVO (TO) on 29/01/2007
Features of the accessory: Pick, moil point

Values related to the vibration worst case handle ​ ( Posterior )
A hx (Mean)
5 m/s2
A hy (Mean)
5.3 m/s2
A hz (Mean)
4.2 m/s2
A hv sum
8.4 m/s2
Standard deviation
0.37 m/s2
Standard deviation
0.63 m/s2
Standard deviation
0.16 m/s2
Standard deviation x 1,645:
0.25 m/s2
Mean
+ Standard deviation:
5.4 m/s2
Mean
+ Standard deviation:
5.9 m/s2
Mean
+ Standard deviation:
4.4 m/s2
A hv sum
+ (Dev. std. x 1,645):
8.7 m/s2
logo regione toscana
Regione Toscana
Diritti Valori Innovazione Sostenibilità
collegamento sito usl 7 siena Servizio Sanitario
della
Toscana