Machine technical sheet


Brand: HILTI
Model: TE 15 C
Type: Rock drills and rotary hammers
Built in: n.d.
Weight: 3.95 kg
Power: 0.71 kW
Power supply: Electrical (220V-380V)
Anti-vibration devices: Absent
Source of the data: Acquisito sul campo da misuratore

Immagine rappresentante la tipologia
Declared values as set forth in the standard EN 50144-2-6
( x 2,0 Hammer drilling, Chiseling, Drilling without impact - x 1,5 Breaking concrete/masonry )
CONDITIONS MATERIAL ACCESSORY VALUE K(1) Note
NOT ASSESSEDNOT ASSESSEDNOT ASSESSED8 m/s2
(1) Expanded uncertainty

Measurements in the field (Click to view the measurements in the field)

Reference person: CPT Perugia ([email protected])
Location: PERUGIA (PG) on 28/05/2007
Features of the accessory: NOT ASSESSED

Values related to the vibration worst case handle ​ ( Left )
A hx (Mean)
5.5 m/s2
A hy (Mean)
5.3 m/s2
A hz (Mean)
3.4 m/s2
A hv sum
8.3 m/s2
Standard deviation
0.34 m/s2
Standard deviation
0.76 m/s2
Standard deviation
0.17 m/s2
Standard deviation x 1,645:
1.16 m/s2
Mean
+ Standard deviation:
5.8 m/s2
Mean
+ Standard deviation:
6.1 m/s2
Mean
+ Standard deviation:
3.6 m/s2
A hv sum
+ (Dev. std. x 1,645):
9.5 m/s2
Reference person: CPT Cagliari ([email protected])
Location: Monastir (CA) on 13/03/2007
Features of the accessory: Chisel

Values related to the vibration worst case handle ​ ( Posterior )
A hx (Mean)
5.8 m/s2
A hy (Mean)
6.9 m/s2
A hz (Mean)
5.8 m/s2
A hv sum
10.7 m/s2
Standard deviation
0.18 m/s2
Standard deviation
0.11 m/s2
Standard deviation
0.22 m/s2
Standard deviation x 1,645:
0.46 m/s2
Mean
+ Standard deviation:
6 m/s2
Mean
+ Standard deviation:
7 m/s2
Mean
+ Standard deviation:
6 m/s2
A hv sum
+ (Dev. std. x 1,645):
11.2 m/s2
Reference person: CPT Perugia ([email protected])
Location: CITTA' DI CASTELLO (PG) on 05/12/2006
Features of the accessory: Pick, moil point

Values related to the vibration worst case handle ​ ( Right )
A hx (Mean)
7.9 m/s2
A hy (Mean)
6.1 m/s2
A hz (Mean)
8.1 m/s2
A hv sum
12.9 m/s2
Standard deviation
0.94 m/s2
Standard deviation
1.09 m/s2
Standard deviation
1.19 m/s2
Standard deviation x 1,645:
3.03 m/s2
Mean
+ Standard deviation:
8.8 m/s2
Mean
+ Standard deviation:
7.2 m/s2
Mean
+ Standard deviation:
9.3 m/s2
A hv sum
+ (Dev. std. x 1,645):
15.9 m/s2
Reference person: CPT Cagliari ([email protected])
Location: Cagliari - Pirri on 12/04/2007
Features of the accessory: Pick, moil point

Values related to the vibration worst case handle ​ ( Anterior )
A hx (Mean)
9.5 m/s2
A hy (Mean)
5.2 m/s2
A hz (Mean)
8.5 m/s2
A hv sum
13.8 m/s2
Standard deviation
0.15 m/s2
Standard deviation
0.08 m/s2
Standard deviation
0.11 m/s2
Standard deviation x 1,645:
0.31 m/s2
Mean
+ Standard deviation:
9.7 m/s2
Mean
+ Standard deviation:
5.3 m/s2
Mean
+ Standard deviation:
8.6 m/s2
A hv sum
+ (Dev. std. x 1,645):
14.1 m/s2