Machine technical sheet


Brand: BMW Motorrad
Model: E 650 G
Type: Motorcycle (scooter) > 50cc
Built in: n.d.
Power: 37 kW
Power supply: Internal combustion gasoline engine
Capacity: 652 cc
Anti-vibration devices: Absent
Source of the data: Acquisito sul campo da misuratore

This machine may also have risks arising from: Whole Body Vibration
Immagine rappresentante la tipologia
Declared values as set forth in the standard EN ISO 5349-1: 2004 - EN ISO 5349-2: 2004
CONDITIONS MATERIAL ACCESSORY VALUE K(1) Note
No declared data
(1) Expanded uncertainty

Measurements in the field (Click to view the measurements in the field)

Reference person: Iole Pinto - Nicola Stacchini - Andrea Bogi AUSL Toscana Sud Est-LSP-Lab. Agenti Fisici ([email protected])
Location: Firenze (FI) on null
Features of the accessory: NOT ASSESSED
Conditions of measurement
Conditions of measurement

Values related to the vibration worst case handle ​ ( Left )
A hx (Mean)
1.1 m/s2
A hy (Mean)
0.9 m/s2
A hz (Mean)
1 m/s2
A hv sum
1.8 m/s2
Standard deviation
0.08 m/s2
Standard deviation
0.4 m/s2
Standard deviation
0.05 m/s2
Standard deviation x 1,645:
0.29 m/s2
Mean
+ Standard deviation:
1.2 m/s2
Mean
+ Standard deviation:
1.3 m/s2
Mean
+ Standard deviation:
1.1 m/s2
A hv sum
+ (Dev. std. x 1,645):
2.1 m/s2
Reference person: Iole Pinto - Nicola Stacchini - Andrea Bogi AUSL Toscana Sud Est-LSP-Lab. Agenti Fisici ([email protected])
Location: Firenze (FI) on 11/05/2009
Features of the accessory: NOT ASSESSED
Conditions of measurement
Conditions of measurement

Values related to the vibration worst case handle ​ ( Left )
A hx (Mean)
1.3 m/s2
A hy (Mean)
1.4 m/s2
A hz (Mean)
1.3 m/s2
A hv sum
2.3 m/s2
Standard deviation
0.38 m/s2
Standard deviation
0.4 m/s2
Standard deviation
0.48 m/s2
Standard deviation x 1,645:
1.07 m/s2
Mean
+ Standard deviation:
1.7 m/s2
Mean
+ Standard deviation:
1.8 m/s2
Mean
+ Standard deviation:
1.8 m/s2
A hv sum
+ (Dev. std. x 1,645):
3.4 m/s2
Reference person: Iole Pinto - Nicola Stacchini - Andrea Bogi AUSL Toscana Sud Est-LSP-Lab. Agenti Fisici ([email protected])
Location: Firenze (FI) on null
Features of the accessory: NOT ASSESSED
Conditions of measurement
Conditions of measurement

Values related to the vibration worst case handle ​ ( Left )
A hx (Mean)
1.6 m/s2
A hy (Mean)
1.8 m/s2
A hz (Mean)
1.4 m/s2
A hv sum
2.8 m/s2
Standard deviation
0.38 m/s2
Standard deviation
2.04 m/s2
Standard deviation
0.27 m/s2
Standard deviation x 1,645:
2.77 m/s2
Mean
+ Standard deviation:
2 m/s2
Mean
+ Standard deviation:
3.8 m/s2
Mean
+ Standard deviation:
1.7 m/s2
A hv sum
+ (Dev. std. x 1,645):
5.6 m/s2
logo regione toscana
Regione Toscana
Diritti Valori Innovazione Sostenibilità
collegamento sito usl 7 siena Servizio Sanitario
della
Toscana