Machine technical sheet


Immagine rappresentane il macchinario
Brand: STAR PROGETTI
Model: Helios Infrared Waterproof
Type: Infrared heaters
Power: 1.5 kW
Power supply: Electrical (220V-380V)
Reference standard: CEI EN 62471
Classification according to standard IEC-EN 62471 / IEC-EN 60825-1: Non disponibile
Category according to standard EN12198-1 Non disponibile

SOURCE TECHNICAL SHEET
Type: lampada a incandescenza n
Emission: Continua
N. of lighting bodies: 1
Brand: Star Progetti
Model: Infracalor Gold
Classification according to standard IEC-EN 62471 / IEC-EN 60825-1: Non disponibile
Reference standard: NON DISPONIBILE

RELEVANT EMISSION TYPES  
                                       
            780 ÷ 3000 (IRA e IRB)    
            780 ÷ 1400 (IRA)                    
        380 ÷ 1400
(Visible and IRA)
                   
      315 ÷ 400
(UVA)
                             
    300 ÷ 700
(Blue light)
                             
  180 ÷ 400
(UVA, UVB e UVC)
                             
⇐ BAND ⇒    
Main protection measures to implement for safety purposes:
  1. Avoid having the source in the field of vision

Measurements in the field (Click to view the measurements in the field)

Reference person:
AUSL 7 Siena - Laboratorio Agenti Fisici Andrea Bogi ([email protected])

Rif.D.lgs 81/08 SPECTRAL RANGE TARGET ORGANS RESULT Val.
a ES (Ultraviolet) Eyes and skin Irrilevante
b EUVA (Ultraviolet A) Eyes Irrilevante
c,d LB (Blue light, extended source) Eyes Esente
e,f EB (Blue light, small source) Eyes Non applicabile
  LAFA (Blue light, extended source, aphakic individuals) Eyes Irrilevante
  EAFA (Blue light, small source,aphakic individuals) Eyes Non applicabile
g,h,i L R (Visible and Infrared A) Eyes Irrilevante 150 W m-2sr-1
j,k,l L R (Infrared A) Eyes Irrilevante 180 W m-2sr-1
m,n EIR (Infrared A + Infrared B) Eyes Non esente: maggiore del VLE 860W m-2
o Eskin (Visible + Infrared A + Infrared B) Skin da 20% ÷ 50% del limite 860 W m-2
SENSOR-SOURCE DISTANCE
80
cm
MAXIMUM EXPOSURE TIME
60
seconds
Reference person:
AUSL 7 Siena - Laboratorio Agenti Fisici Andrea Bogi ([email protected])

Rif.D.lgs 81/08 SPECTRAL RANGE TARGET ORGANS RESULT Val.
a ES (Ultraviolet) Eyes and skin Irrilevante
b EUVA (Ultraviolet A) Eyes Irrilevante
c,d LB (Blue light, extended source) Eyes da 20% ÷ 50% del limite 30 W m-2sr-1
e,f EB (Blue light, small source) Eyes Non applicabile
  LAFA (Blue light, extended source, aphakic individuals) Eyes Non disponibile
  EAFA (Blue light, small source,aphakic individuals) Eyes Non applicabile
g,h,i L R (Visible and Infrared A) Eyes Irrilevante 1200 W m-2sr-1
j,k,l L R (Infrared A) Eyes Irrilevante 1200 W m-2sr-1
m,n EIR (Infrared A + Infrared B) Eyes Non esente: maggiore del VLE 142W m-2
o Eskin (Visible + Infrared A + Infrared B) Skin Irrilevante 142 W m-2
SENSOR-SOURCE DISTANCE
180
cm
MAXIMUM EXPOSURE TIME
600
seconds
Reference person:
AUSL 7 Siena - Laboratorio Agenti Fisici Andrea Bogi ([email protected])

Rif.D.lgs 81/08 SPECTRAL RANGE TARGET ORGANS RESULT Val.
a ES (Ultraviolet) Eyes and skin Irrilevante
b EUVA (Ultraviolet A) Eyes Irrilevante
c,d LB (Blue light, extended source) Eyes Irrilevante 23 W m-2sr-1
e,f EB (Blue light, small source) Eyes Non applicabile
  LAFA (Blue light, extended source, aphakic individuals) Eyes Non disponibile
  EAFA (Blue light, small source,aphakic individuals) Eyes Non applicabile
g,h,i L R (Visible and Infrared A) Eyes Irrilevante 1500 W m-2sr-1
j,k,l L R (Infrared A) Eyes Irrilevante 1400 W m-2sr-1
m,n EIR (Infrared A + Infrared B) Eyes da 50% ÷ 80% del limite 80W m-2
o Eskin (Visible + Infrared A + Infrared B) Skin Irrilevante 80 W m-2
SENSOR-SOURCE DISTANCE
245
cm
SAFETY RADIAL DISTANCE
250
cm
logo regione toscana
Regione Toscana
Diritti Valori Innovazione Sostenibilità
collegamento sito usl 7 siena Servizio Sanitario
della
Toscana
eventi
CORSO FAD SINCRONA
Esposizione occupazionale ai campi
elettromagnetici
06-07 maggio
Corso online
~
CORSO AIDII TER
II EDIZIONE
19-22-27 maggio
e 3 giugno 2025
Corso online
~
Corso di formazione
Rischio VIBRAZIONI
03 giugno 2025
Corso online
~
Corso di formazione
Rischio RUMORE
06 giugno 2025
Corso online
~
Corso di formazione
Rischio MICROCLIMA
7 luglio 2025
Corso online
~
Corso di aggiornamento
Rischio MICROCLIMA
2 Aprile 2025
Corso online
~
Rischio ULTRASUONI
Aggiornamenti e strumenti operativi
2 Aprile 2025
Corso online
~
Corso AIDII TER
Valutatore di radiazioni ottiche
1-3-8-10 Aprile 2025
Corso online
~
Corso di formazione
Il rischio da agenti fisici:
Fondamenti
30 e 31 Gennaio 2025
CNR Area Territoriale di Ricerca di Firenze
~
Corso di alta formazione
Gestione integrata del rischio da agenti fisici
Scadenza presentazione
23 gennaio 2025
Sapienza- Università di Roma
~
Rischio da esposizione a vibrazione:
valutazione e controllo
in differenti condizioni espositive
10 Dicembre 2024
Corso online
~
Rischio rumore:
valutazione e controllo
in differenti condizioni espositive
28 Novembre 2024
Corso online
~
Corso di formazione:
Microclima
Rischio alla luce
dei cambiamenti climatici
7 Novembre 2024
Corso online
~
Corso di formazione:
Rischio da esposizione a rumore
14 Ottebre
Corso online
~
Convegno Nazionale
OspedaleSicuro Duemila24
3 e 4 Ottobre 2024
Università degli studi di Napoli "Federico II"
~
Corso di formazione:
Rischio da esposizione a rumore
7 Maggio 2024
Corso online
~
Corso di formazione:
Microclima
per Associazione
Ambientale Lavoro
27 Febbraio 2024
Corso online
~
Giornata Studio:
Valutazione e gestione
del rischio da esposizione
31 Ottobre 2023
Politecnico di Torino
~
Corso di formazione:
Ultrasuoni - Microclima
Vibrazioni
30 Novembre - 1° Dicembre 2023
~