RELEVANT EMISSION TYPES | |||||||||||||||||||
780 ÷ 3000 (IRA e IRB) | |||||||||||||||||||
780 ÷ 1400 (IRA) | |||||||||||||||||||
380 ÷ 1400 (Visible and IRA) |
|||||||||||||||||||
315 ÷ 400 (UVA) |
|||||||||||||||||||
300 ÷ 700 (Blue light) |
|||||||||||||||||||
180 ÷ 400 (UVA, UVB e UVC) |
|||||||||||||||||||
⇐ BAND ⇒ |
TYPE OF MEASUREMENT: DIRECT SECTOR: Restaurants, work canteens and cafés ORIGINAL LAMPS: Yes GEOMETRY OF THE MEASUREMENT: posizione generica 20 cm |
Rif.D.lgs 81/08 | SPECTRAL RANGE | TARGET ORGANS | RESULT | Val. |
---|---|---|---|---|
a | ES (Ultraviolet) | Eyes and skin | Irrilevante | |
b | EUVA (Ultraviolet A) | Eyes | Irrilevante | |
c,d | LB (Blue light, extended source) | Eyes | Irrilevante | |
e,f | EB (Blue light, small source) | Eyes | Non applicabile | |
LAFA (Blue light, extended source, aphakic individuals) | Eyes | Non disponibile | ||
EAFA (Blue light, small source,aphakic individuals) | Eyes | Non applicabile | ||
g,h,i | L R (Visible and Infrared A) | Eyes | Irrilevante | |
j,k,l | L R (Infrared A) | Eyes | Irrilevante | |
m,n | EIR (Infrared A + Infrared B) | Eyes | Maggiore del VLE | 1870W m-2 |
o | Eskin (Visible + Infrared A + Infrared B) | Skin | da 50% ÷ 80% del limite | 1870 W m-2 |
SENSOR-SOURCE DISTANCE | |
20
cm
|
MAXIMUM EXPOSURE TIME | |
20
seconds
|
TYPE OF MEASUREMENT: DIRECT SECTOR: Restaurants, work canteens and cafés ORIGINAL LAMPS: Yes GEOMETRY OF THE MEASUREMENT: posizione generica 130 cm |
SAFETY DISTANCE
120
cm
|
Rif.D.lgs 81/08 | SPECTRAL RANGE | TARGET ORGANS | RESULT | Val. |
---|---|---|---|---|
a | ES (Ultraviolet) | Eyes and skin | Irrilevante | |
b | EUVA (Ultraviolet A) | Eyes | Irrilevante | |
c,d | LB (Blue light, extended source) | Eyes | Irrilevante | |
e,f | EB (Blue light, small source) | Eyes | Non applicabile | |
LAFA (Blue light, extended source, aphakic individuals) | Eyes | Non disponibile | ||
EAFA (Blue light, small source,aphakic individuals) | Eyes | Non disponibile | ||
g,h,i | L R (Visible and Infrared A) | Eyes | Irrilevante | |
j,k,l | L R (Infrared A) | Eyes | Irrilevante | |
m,n | EIR (Infrared A + Infrared B) | Eyes | da 50% ÷ 80% del limite | 70W m-2 |
o | Eskin (Visible + Infrared A + Infrared B) | Skin | Irrilevante |
SENSOR-SOURCE DISTANCE | |
130
cm
|
MAXIMUM EXPOSURE TIME | |
1634
seconds
|
SAFETY RADIAL DISTANCE | |
120
cm
|
TYPE OF MEASUREMENT: DIRECT SECTOR: Restaurants, work canteens and cafés ORIGINAL LAMPS: Yes GEOMETRY OF THE MEASUREMENT: posizione generica 80 cm |
Rif.D.lgs 81/08 | SPECTRAL RANGE | TARGET ORGANS | RESULT | Val. |
---|---|---|---|---|
a | ES (Ultraviolet) | Eyes and skin | Irrilevante | |
b | EUVA (Ultraviolet A) | Eyes | Irrilevante | |
c,d | LB (Blue light, extended source) | Eyes | Irrilevante | |
e,f | EB (Blue light, small source) | Eyes | Non applicabile | |
LAFA (Blue light, extended source, aphakic individuals) | Eyes | Non disponibile | ||
EAFA (Blue light, small source,aphakic individuals) | Eyes | Non disponibile | ||
g,h,i | L R (Visible and Infrared A) | Eyes | Irrilevante | |
j,k,l | L R (Infrared A) | Eyes | Irrilevante | |
m,n | EIR (Infrared A + Infrared B) | Eyes | Maggiore del VLE | 156W m-2 |
o | Eskin (Visible + Infrared A + Infrared B) | Skin | Irrilevante |
SENSOR-SOURCE DISTANCE | |
80
cm
|
MAXIMUM EXPOSURE TIME | |
561
seconds
|
In order to use the related data in the proper way, the user should first look through the documents contained in the "Guide for using the Database" for each single Physical Agent. We decline any liability arising from an improper use of the data and information contained in the Databases and in the Portal.