Machine technical sheet


Immagine rappresentane il macchinario
Brand: HEDSON Technologies Sweden
Model: Curemaster super TRISK ETS2
Type: Infrared dryers
Power: 3.3 kW
Power supply: Electrical (220V-380V)
Reference standard: NON DISPONIBILE
Classification according to standard IEC-EN 62471 / IEC-EN 60825-1: Non disponibile
Category according to standard EN12198-1 Non disponibile

SOURCE TECHNICAL SHEET
Type: lampada a incandescenza n
Emission: Continua
N. of lighting bodies: 3
Brand: NON DISPONIBILE
Model: NON DISPONIBILE
Classification according to standard IEC-EN 62471 / IEC-EN 60825-1: Non disponibile
Reference standard: NON DISPONIBILE

RELEVANT EMISSION TYPES  
                                       
            780 ÷ 3000 (IRA e IRB)    
            780 ÷ 1400 (IRA)                    
        380 ÷ 1400
(Visible and IRA)
                   
      315 ÷ 400
(UVA)
                             
    300 ÷ 700
(Blue light)
                             
  180 ÷ 400
(UVA, UVB e UVC)
                             
⇐ BAND ⇒    
Main protection measures to implement for safety purposes:
  1. Avoid having the source in the field of vision
  2. It is necessary to protect the eyes if the source is in the field of vision for a time that exceeds the indicated maximum time
  3. It is mandatory to train the operators: the exposure is relevant if the operators are not informed about the appropriate operation modes

Measurements in the field (Click to view the measurements in the field)

Reference person:
AUSL 7 Siena - Laboratorio Agenti Fisici Andrea Bogi ([email protected])

Rif.D.lgs 81/08 SPECTRAL RANGE TARGET ORGANS RESULT Val.
a ES (Ultraviolet) Eyes and skin Irrilevante
b EUVA (Ultraviolet A) Eyes Irrilevante
c,d LB (Blue light, extended source) Eyes Irrilevante
e,f EB (Blue light, small source) Eyes Non applicabile
  LAFA (Blue light, extended source, aphakic individuals) Eyes Irrilevante
  EAFA (Blue light, small source,aphakic individuals) Eyes Non applicabile
g,h,i L R (Visible and Infrared A) Eyes Irrilevante
j,k,l L R (Infrared A) Eyes Irrilevante
m,n EIR (Infrared A + Infrared B) Eyes Maggiore del VLE 420W m-2
o Eskin (Visible + Infrared A + Infrared B) Skin Irrilevante 420 W m-2
SENSOR-SOURCE DISTANCE
100
cm
MAXIMUM EXPOSURE TIME
150
seconds
SAFETY RADIAL DISTANCE
250
cm
Note: Dimensioni relative alla singola lampada alogena
Reference person:
AUSL 7 Siena - Laboratorio Agenti Fisici Andrea Bogi ([email protected])

Rif.D.lgs 81/08 SPECTRAL RANGE TARGET ORGANS RESULT Val.
a ES (Ultraviolet) Eyes and skin Irrilevante
b EUVA (Ultraviolet A) Eyes Irrilevante
c,d LB (Blue light, extended source) Eyes Irrilevante
e,f EB (Blue light, small source) Eyes Non applicabile
  LAFA (Blue light, extended source, aphakic individuals) Eyes Irrilevante
  EAFA (Blue light, small source,aphakic individuals) Eyes Non applicabile
g,h,i L R (Visible and Infrared A) Eyes Irrilevante
j,k,l L R (Infrared A) Eyes Irrilevante
m,n EIR (Infrared A + Infrared B) Eyes da 20% ÷ 50% del limite 30W m-2
o Eskin (Visible + Infrared A + Infrared B) Skin Irrilevante 30 W m-2
SENSOR-SOURCE DISTANCE
130
cm
logo regione toscana
Regione Toscana
Diritti Valori Innovazione Sostenibilità
collegamento sito usl 7 siena Servizio Sanitario
della
Toscana